 +====== July 5, 2010 ======
 +The mesh network at DGP went down a couple of days ago.  I emailed staff to ask them to powercycle the rinkhouse router, but the network didn't come back up, so I went by to take a look.  There was no signal outside the rinkhouse. ​ I powercycled the router, and it didn't come up.  I got a ladder to take a look at the router, and the LEDs weren'​t on.  I took the router down and plugged it directly into the powersupply and the lights came on.  So I think the problem is one of:
 +1) The ethernet run from the kitchen (where the power supply is) to the rinkhouse router is damaged.
 +2) The PoE injector is faulty.
 +3) The internal PoE splitter inside the router is faulty.
 +
 +It's almost certainly the Ethernet cable. ​ I didn't have a spare patch cable to test with.  I think we should just go back with a patch cable and a length of cable and a crimper -- test with the patch cable, and assuming it works just right away run a new Ethernet line.  Bring lots of cable clips, and a hammer drill -- if the cable is secure in more places, it's less likely to be damaged from strain. ​ I think.
 +
 ====== August 21, 2009 ====== ====== August 21, 2009 ======
 Wifidog and Open-mesh started reporting that the DGP nodes were down again starting a few weeks ago.  (The network ran for about a week after the outage which ended July 19.)  Eventually the folks at the park identified that the modem was the problem. ​ They called the ISP and had them reassign the service to another router, which also didn't work.  Gabe went in a few days ago to test both modems, knowing that the power supplies flake out frequently. ​ Of the two modems and two power supplies they had, one of each worked. ​ But it wasn't the modem that had the service associated with it.  ​ Wifidog and Open-mesh started reporting that the DGP nodes were down again starting a few weeks ago.  (The network ran for about a week after the outage which ended July 19.)  Eventually the folks at the park identified that the modem was the problem. ​ They called the ISP and had them reassign the service to another router, which also didn't work.  Gabe went in a few days ago to test both modems, knowing that the power supplies flake out frequently. ​ Of the two modems and two power supplies they had, one of each worked. ​ But it wasn't the modem that had the service associated with it.  ​